EA sampling point

Wey at Friary Bridge, Guildford

Sampled by the Environment Agency on 3 visits in 2025. Phosphate averages moderate, below the good standard. Ammonia and dissolved oxygen are high. Averages are over 2023–2025.

Phosphate

2025: avg 0.130 · max 0.140 mg/l

Band, 2023–2025 average: 0.149 · Moderate

00.050.10.150.22025-01-16: 0.14 mg/l2025-02-11: 0.13 mg/l2025-03-13: 0.12 mg/l
High ≤ 0.036Good ≤ 0.069Moderate ≤ 0.173Poor ≤ 1.003Bad > 1.003

Ammonia

2025: avg 0.079 · max 0.096 mg/l

Band, 2023–2025 average: 0.054 · High

00.20.40.62025-01-16: 0.096 mg/l2025-02-11: 0.095 mg/l2025-03-13: 0.047 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2025: avg 98 · min 96 % saturation

Band, 2023–2025 average: 96 · High

60801001202025-01-16: 97.4 % saturation2025-02-11: 95.6 % saturation2025-03-13: 101.1 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

5.6–8.1 °C

Warm water holds less oxygen. There is no river standard for temperature here.

02.557.5102025-01-16: 7.2 °C2025-02-11: 5.6 °C2025-03-13: 8.1 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: Conductivity at 25 C (MICROSIEMENS PER CENTIMETRE)

EA sampling point TH-PWER0326 · Wey (Shalford to River Thames confluence at Weybridge) · 317 readings of 17 tests since 2021.

DateResultUnitSample
2025-03-13 12:19434MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2025-02-11 12:51388MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2025-01-16 15:12425MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-12-06 09:58335MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-11-11 13:15425MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-10-10 14:46308MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-09-20 14:30407MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-08-07 14:08421MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-07-04 09:32460MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-06-27 11:17440MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2021-08-17 10:35421MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-08-17 10:34421MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-07-05 10:35423MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-07-05 10:34423MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-06-01 14:27428MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-06-01 14:25428MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-05-18 12:29379MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-05-18 12:27379MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-04-14 13:45434MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-03-11 11:47444MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-02-04 11:19344MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-01-12 14:09424MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)

Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the River Wey.

Wey at Friary Bridge, Guildford: EA water tests — River Wey Data