EA sampling point

Wey at Friary Bridge, Guildford

Sampled by the Environment Agency on 10 visits from 2023 to 2025. Phosphate averages moderate, below the good standard. Ammonia and dissolved oxygen are high. Averages are over 2023–2025.

Phosphate

2023–2025: avg 0.149 · max 0.170 mg/l

Band, 2023–2025 average: 0.149 · Moderate

00.050.10.150.2202420252024-06-27: 0.16 mg/l2024-07-04: 0.17 mg/l2024-08-07: 0.16 mg/l2024-09-20: 0.16 mg/l2024-10-10: 0.17 mg/l2024-11-11: 0.13 mg/l2025-01-16: 0.14 mg/l2025-02-11: 0.13 mg/l2025-03-13: 0.12 mg/l
High ≤ 0.036Good ≤ 0.069Moderate ≤ 0.173Poor ≤ 1.003Bad > 1.003

Ammonia

2023–2025: avg 0.054 · max 0.096 mg/l

Band, 2023–2025 average: 0.054 · High

00.20.40.6202420252024-06-27: 0.048 mg/l2024-07-04: 0.052 mg/l2024-08-07: 0.035 mg/l2024-09-20: 0.052 mg/l2024-10-10: below 0.03 mg/l2024-11-11: 0.046 mg/l2025-01-16: 0.096 mg/l2025-02-11: 0.095 mg/l2025-03-13: 0.047 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2023–2025: avg 96 · min 93 % saturation

Band, 2023–2025 average: 96 · High

6080100120202420252024-06-27: 96.8 % saturation2024-07-04: 95.7 % saturation2024-08-07: 93.9 % saturation2024-09-20: 95.2 % saturation2024-10-10: 93.7 % saturation2024-11-11: 94.5 % saturation2024-12-06: 93.2 % saturation2025-01-16: 97.4 % saturation2025-02-11: 95.6 % saturation2025-03-13: 101.1 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

5.6–18.5 °C

Warm water holds less oxygen. There is no river standard for temperature here.

05101520202420252024-06-27: 18.5 °C2024-07-04: 15.1 °C2024-08-07: 17.6 °C2024-09-20: 15.9 °C2024-10-10: 13.3 °C2024-11-11: 10.2 °C2024-12-06: 8.7 °C2025-01-16: 7.2 °C2025-02-11: 5.6 °C2025-03-13: 8.1 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: Conductivity at 25 C (MICROSIEMENS PER CENTIMETRE)

EA sampling point TH-PWER0326 · Wey (Shalford to River Thames confluence at Weybridge) · 317 readings of 17 tests since 2021.

DateResultUnitSample
2025-03-13 12:19434MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2025-02-11 12:51388MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2025-01-16 15:12425MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-12-06 09:58335MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-11-11 13:15425MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-10-10 14:46308MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-09-20 14:30407MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-08-07 14:08421MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-07-04 09:32460MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2024-06-27 11:17440MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (NATIONAL AGENCY POLICY)
2021-08-17 10:35421MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-08-17 10:34421MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-07-05 10:35423MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-07-05 10:34423MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-06-01 14:27428MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-06-01 14:25428MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-05-18 12:29379MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-05-18 12:27379MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-04-14 13:45434MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-03-11 11:47444MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-02-04 11:19344MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2021-01-12 14:09424MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)

Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the River Wey.