EA sampling point

Wey at Burpham Court Bridge

Sampled by the Environment Agency on 16 visits from 2021 to 2024.

No phosphate, ammonia or dissolved-oxygen tests here in this period. Every other reading is below.

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: Cypermethrin (MICROGRAM PER LITRE)

EA sampling point TH-PWER0033 · Wey (Shalford to River Thames confluence at Weybridge) · 78 readings of 10 tests since 2021.

DateResultUnitSample
2022-03-24 12:140.00002MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2022-02-03 12:300.00004MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2022-01-05 12:320.00004MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-12-03 13:160.00003MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-11-10 12:480.00003MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-10-05 10:090.00003MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-09-14 11:230.00006MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-08-04 10:50< 0.00002MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-07-05 09:47< 0.00001MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-06-17 10:500.00005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-05-05 10:010.00001MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-04-06 13:12< 0.00001MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)

Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the River Wey.