NRW sampling point

Maesteilo Mansion FE

Sampled by Natural Resources Wales on 4 visits in 2026.

Phosphate

2026: avg 3.268 · max 5.160 mg/l
02.557.5102026-03-11: 1.63 mg/l2026-04-16: 2.98 mg/l2026-06-22: 3.3 mg/l2026-08-13: 5.16 mg/l
High ≤ 0.036Good ≤ 0.069Moderate ≤ 0.173Poor ≤ 1.003Bad > 1.003

Ammonia

2026: avg 36.125 · max 52.800 mg/l
02550751002026-03-11: 18.4 mg/l2026-04-16: 34.9 mg/l2026-06-22: 38.4 mg/l2026-08-13: 52.8 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2026: avg 14 · min 3 % saturation
02550751001252026-03-11: 29 % saturation2026-04-16: 16.5 % saturation2026-06-22: 8.3 % saturation2026-08-13: 3.3 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

11.9–23.2 °C

Warm water holds less oxygen. There is no river standard for temperature here.

02040602026-03-11: 11.9 °C2026-04-16: 14.2 °C2026-06-22: 20.4 °C2026-08-13: 23.2 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative:Natural Resources Wales’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: Ammoniacal Nitrogen as N (mg/l)

NRW sampling point S6030147 · 40 readings of 10 tests since 2026.

DateResultUnitSample
2026-08-13 11:4152.8mg/lFINAL SEWAGE EFFLUENT · COMPLIANCE AUDIT (PERMIT)
2026-06-22 12:2638.4mg/lFINAL SEWAGE EFFLUENT · COMPLIANCE AUDIT (PERMIT)
2026-04-16 09:5134.9mg/lFINAL SEWAGE EFFLUENT · COMPLIANCE AUDIT (PERMIT)
2026-03-11 14:4118.4mg/lFINAL SEWAGE EFFLUENT · COMPLIANCE AUDIT (PERMIT)

Source: Natural Resources Wales Open Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the River Tywi.

Maesteilo Mansion FE: NRW water tests — Afon Tywi / River Tywi Data