Dry spilling
A spill in dry weather has no rainfall to excuse it. The same overflows do it year after year.
A storm overflow may discharge only in exceptional circumstances. Regular spilling in normal or moderate rainfall is a prima facie breach of regulation 4 of the Urban Waste Water Treatment Regulations 1994.
This reading follows the Office for Environmental Protection's December 2024 findings against Defra, the Environment Agency and Ofwat, which set out a two-stage test — was the discharge caused by exceptional circumstances, and was it nonetheless kept to a minimum — and Defra's 24 March 2025 guidance, which supersedes the 1997 guidance the regulators had relied on.
Repeat dry-weather offenders
| Overflow | Years | Dry spills | On record |
|---|---|---|---|
| South Moreton STW TWL00378 | 3 | 427 | Measure linked |
| Cirencester STW TWL00102 | 3 | 162 | Measure linked |
| Wanborough STW TWL00422 | 3 | 136 | Measure linked |
| Windsor STW TWL00452 | 3 | 104 | Measure linked |
| Pangbourne STW TWL00324 | 3 | 49 | Measure linked |
| Fairford STW TWL00178 | 3 | 48 | Measure linked |
| Shrivenham STW TWL00368 | 3 | 42 | Measure linked |
| Cricklade STW TWL00119 | 3 | 38 | Measure linked |
| Compton STW TWL00112 | 3 | 34 | No measure |
| Hatchetts (cricklade) pumping station TWL00600 | 3 | 29 | No measure |
| Hampstead Norreys STW TWL00211 | 3 | 28 | Measure linked |
| Sevenhampton STW TWL00362 | 3 | 21 | No measure |
| Slough STW TWL00397 | 3 | 17 | No measure |
| Ampney St Peter STW TWL00010 | 3 | 10 | Measure linked |
| Briff Lane (bucklebury) STW TWL00061 | 2 | 53 | No measure |
| Bracknell STW TWL00051 | 2 | 10 | Measure linked |
| Chapel Row STW TWL00081 | 2 | 7 | No measure |
| Crossness STW TWL00123 | 2 | 4 | No measure |
| Low Level Xx, Grosvenor Ditch, Millb TWL00596 | 2 | 3 | No measure |
| Friday Street (henley) pumping station TWL00191 | 2 | 3 | No measure |
| Long Reach STW TWL00277 | 2 | 3 | No measure |
| Iron Gate TWL00241 | 2 | 3 | No measure |
Each overflow's per-spill confidence (gauge proximity, antecedent-dry window, monitor uptime) is shown on every event's evidence dossier.
How we decide a spill was dry
A spill is counted as dry when rainfall at the nearest gauge was ≤ 0.25 mm on the spill day and the day before, and the spill lasted at least 15 minutes. Confidence rises with a closer gauge, a longer antecedent-dry window, and a monitor that was reporting reliably. Read the full method →
Why this now carries more weight
A dry-day spill is a pollution incident regardless of its volume. Dry-spill frequency is a scored metric in the Environment Agency's 2026–30 regime, and updated incident guidance removes companies' former latitude to downgrade these events. A pattern of them is exactly what a regulator is now expected to act on.
Dry-spill method ↗ · figures reproducible against the pinned method version.