Why it keeps happening
Three things we can measure in the data. None of them proves a cause on its own, but each points at a different kind of infrastructure problem.
A discharge in dry weather is not an exceptional circumstance, so it is not permitted on any reading of regulation 4.
See the 38 →A strong signal, not a finding. We cannot see whether flow is transferred to another works for treatment, and the permitted figure is not always published.
See the 0 →Rainfall across the catchment does not explain a discharge that an overflow's own treatment works did not share.
See the 99 →Where the indicators concentrate
| Overflow | Hours | Dry | What it points to | Verdict |
|---|---|---|---|---|
| Harewood Rd, CalstockCSO | 1,010 | 17 | Very long spills | No action |
| Trebullett STWSO | 1,317 | 120 | High spill frequency | No action |
| Playing Fields, CalstockPS-CSO/EO | 653 | 9 | Spills before its works | No action |
| Beals Mill STW, RezareSO | 1,715 | 234 | High spill frequency | No action |
| Polyphant pumping stationPS-CSO/EO | 1,684 | 84 | Very long spills | No action |
| St Dominick STW, CallingtonSO | 1,665 | 46 | High spill frequency | No action |
| Bere Alston STWSSO | 974 | 18 | Very long spills | No action |
| Gunnislake STWSSO | 947 | 34 | Very long spills | No action |
| Marsh Mills STW, PlymptonSSO | 864 | 47 | High spill frequency | No action |
| Central STW Shaft 16 pumping station, PlymouPS-CSO/EO | 911 | 12 | High spill frequency | No action |
Hours are the last full year; dry spills are since 2020. Verdict is whether a measure is linked to the overflow — see the gaps.
What this analysis cannot see
These indicators are measured from spill timing and rainfall alone. They cannot see misconnections, the quality of effluent from a works that is running normally, flow transferred between works for treatment, a company's maintenance history, or the periods when a monitor was offline. Because a quiet monitor records nothing, every count here is a floor, not a total.