Why it keeps happening
Three things we can measure in the data. None of them proves a cause on its own, but each points at a different kind of infrastructure problem.
A discharge in dry weather is not an exceptional circumstance, so it is not permitted on any reading of regulation 4.
See the 7 →A strong signal, not a finding. We cannot see whether flow is transferred to another works for treatment, and the permitted figure is not always published.
See the 0 →Rainfall across the catchment does not explain a discharge that an overflow's own treatment works did not share.
See the 1 →Where the indicators concentrate
| Overflow | Hours | Dry | What it points to | Verdict |
|---|---|---|---|---|
| Ludgershall STW | 617 | 23 | Dry spilling | On record |
| Charlton-on-otmoor STW | 814 | 71 | Dry spilling | On record |
| Islip STW | 697 | 25 | Dry spilling | On record |
| Weston-on-the-green STW | 696 | 6 | Very long spills | No action |
| Bicester STW | 450 | 48 | Dry spilling | On record |
| Bletchingdon STW | 302 | 32 | Dry spilling | On record |
| Grendon Underwood STW | 306 | 7 | Dry spilling | No action |
| Middleton Stoney STW | 145 | 6 | Dry spilling | On record |
| Xx (bucknell) pumping station | 0 | 0 | Spills before its works | No action |
Hours are the last full year; dry spills are since 2020. Verdict is whether a measure is linked to the overflow — see the gaps.
What this analysis cannot see
These indicators are measured from spill timing and rainfall alone. They cannot see misconnections, the quality of effluent from a works that is running normally, flow transferred between works for treatment, a company's maintenance history, or the periods when a monitor was offline. Because a quiet monitor records nothing, every count here is a floor, not a total.