What the regulator requires
A measure is a specific action the regulator requires the water company to take at a named site — to investigate a problem, keep monitoring it, or physically fix it — each with a completion date. These are the legally binding measures on record for this catchment: what each requires, and what to watch.
These measures are legally binding. Each one is a dated, site-specific requirement the company must deliver.
The Water Industry National Environment Programme is how the Environment Agency turns statutory duties into named obligations at named sites, with a completion date attached. Where a measure requires a physical upgrade, the Agency writes the result into the site's environmental permit — and from that point the requirement is criminally enforceable.
The measure itself is public. What is not published is the water company's action to comply with it — its delivery is reported to the regulator and scored, but the underlying work, and whether a measure has actually resolved the problem on the ground, is not on the public record. What to watch is slippage: a measure can be re-dated or re-scoped, and until the permit is varied the obligation has not changed.
What the types mean
A physical upgrade — bigger storage, better treatment, more capacity. This is the only type that actually fixes the problem on the ground.
A study of the cause. It produces a report, not a repair — an investigation must lead to an improvement before anything changes.
Installing or running instruments to measure the problem. Necessary evidence, but on its own it fixes nothing — it too has to be followed by an improvement.
So an overflow whose only measures are investigations or monitoring is being looked at, not yet fixed. On the gaps page, only a measure that is still active counts as action — a measure completed while the overflow is still failing does not.
| Reference | Driver | Type | What it requires | Status | Attached to |
|---|---|---|---|---|---|
| 08TW100542 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) ABINGDON SEWAGE TREATMENT WORKS (Odhay Hill Ditch) | Complete 2025-26 | Thames (Evenlode to Thame) |
| 08TW100547 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) APPLETON STW, ABINGDON, OXON | Complete 2025-26 | Frilford and Marcham Brook |
| 08TW100570 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) CASSINGTON STW | Complete 2025-26 | Cassington STW |
| 08TW100590 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) CULHAM STW | Complete 2025-26 | Culham STW |
| 08TW100592 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) DIDCOT STW | Complete 2025-26 | Didcot STW |
| 08TW100595 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) DRAYTON STW | Complete 2025-26 | Drayton STW |
| 08TW100633 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) KINGSTON BAGPUIZE STW | Complete 2025-26 | Kingston Bagpuize STW |
| 08TW100716 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) OXFORD (SANDFORD) STW | Complete 2025-26 | Northfield Brook (Source to Thames) at Sandford |
| 08TW100667 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) STANFORD IN THE VALE STW | Complete 2025-26 | Stanford in the Vale STW |
| 08TW100674 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) UFFINGTON STW | Complete 2025-26 | Uffington STW |
| 08TW100677 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) WANTAGE STW | Complete 2025-26 | Wantage STW |
| 08TW101392 · a | WFD_ND | No deterioration | mg/l Amm permit at CULHAM STW Reduce ammonia loading | Complete 2025-26 | Thames (Evenlode to Thame) |
| 08TW101393 · a | WFD_ND | No deterioration | mg/l BOD permit at CULHAM STW Reduce BOD loading | Complete 2025-26 | Thames (Evenlode to Thame) |
| 08TW100863 · a | EnvAct_IMP1 | Improvement | 0.25 mg/l Phosphorus permit at Appleton STW Reduce Phosphorus Loadings at Appleton STW | Complete 2025-26 | Frilford and Marcham Brook |
| 08TW101567 · a | U_MON4 | Monitoring | Install and run event-duration monitoring ABINGDON SEWAGE TREATMENT WORKS (Odhay Hill Ditch) | Due 2026-27 | Thames (Evenlode to Thame) |
| 08TW100285 · a | U_MON4 | Monitoring | Move AMP7 U_MON4 driver output to 2-minute flow monitoring (U_MON4a) APPLETON STW, ABINGDON, OXON | Due 2026-27 | Frilford and Marcham Brook |
| 08TW100306 · a | U_MON4 | Monitoring | Move AMP7 U_MON4 driver output to 2-minute flow monitoring (U_MON4a) CASSINGTON STW | Due 2026-27 | Cassington STW |
| 08TW101583 · a | U_MON4 | Monitoring | Install and run event-duration monitoring CULHAM STW | Due 2026-27 | Culham STW |
| 08TW100429 · a | U_MON4 | Monitoring | Install and run event-duration monitoring DIDCOT STW | Due 2026-27 | Didcot STW |
| 08TW101586 · a | U_MON4 | Monitoring | Install and run event-duration monitoring DRAYTON STW | Due 2026-27 | Drayton STW |
| 08TW100354 · a | U_MON4 | Monitoring | Move AMP7 U_MON4 driver output to 2-minute flow monitoring (U_MON4a) KINGSTON BAGPUIZE STW | Due 2026-27 | Kingston Bagpuize STW |
| 08TW101603 · a | U_MON4 | Monitoring | Install and run event-duration monitoring OXFORD (SANDFORD) STW | Due 2026-27 | Northfield Brook (Source to Thames) at Sandford |
| 08TW100385 · a | U_MON4 | Monitoring | Move AMP7 U_MON4 driver output to 2-minute flow monitoring (U_MON4a) STANFORD IN THE VALE STW | Due 2026-27 | Stanford in the Vale STW |
| 08TW100395 · a | U_MON4 | Monitoring | Move AMP7 U_MON4 driver output to 2-minute flow monitoring (U_MON4a) UFFINGTON STW | Due 2026-27 | Uffington STW |
| 08TW100451 · a | U_MON4 | Monitoring | Install and run event-duration monitoring WANTAGE STW | Due 2026-27 | Wantage STW |
| 08TW101108 · gr | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at CASSINGTON STW | Due 2027-28 | Thames (Evenlode to Thame) |
| 08TW101108 · ur | EnvAct_INV4 | Investigation | Storm Overflows investigation Tubney SPS (AKA Basildon House)- Storm Overflows investigation | Due 2027-28 | Frilford and Marcham Brook |
| 08TW100052 · c | WFD_INV_CHEM | Investigation | Oxford STW 4e Emerging substances investigation – impact to the environment | Due 2029-30 | Northfield Brook (Source to Thames) at Sandford |
| 08TW100897 · a | EnvAct_IMP1 | Improvement | 0.25 mg/l Phosphorus permit at Culham STW Reduce Phosphorus Loadings at Culham STW | Due 2029-30 | Thames (Evenlode to Thame) |
| 08TW100899 · a | EnvAct_IMP1 | Improvement | 0.25 mg/l Phosphorus permit with stretch target of 0.2 mg/l at Didcot STW Reduce Phosphorus Loadings at Didcot STW | Due 2029-30 | Moor Ditch and Ladygrove Ditch |
| 08TW100924 · a | EnvAct_IMP1 | Improvement | 0.25 mg/l Phosphorus permit with stretch target of 0.15 mg/l at Oxford STW Reduce Phosphorus Loadings at Oxford STW | Due 2029-30 | Northfield Brook (Source to Thames) at Sandford |
| 08TW100942 · a | EnvAct_IMP1 | Improvement | 0.25 mg/l Phosphorus permit with stretch target of 0.2 mg/l at Tring STW Reduce Phosphorus Loadings at Tring STW | Due 2029-30 | Ock (to Cherbury Brook) |
| 09TW100048 · a | EnvAct_IMP1 | Improvement | 0.25 mg/l Phosphorus permit at Wantage STW Reduce Phosphorus Loadings at Wantage STW | Due 2029-30 | Letcombe Brook |
| 08TW101087 · a | EnvAct_IMP3 | Improvement | Option C1: Investigation and Solution in AMP 8: FFT Equivalent, 4.58Ha SUDS IA Removal, 40m3 screen Storm Overflows action at CASSINGTON STW | Due 2029-30 | Thames (Evenlode to Thame) |
34 of 34 measures shown. A measure whose completion date has passed is shown as Complete; the water company's actual delivery against it is reported to the regulator but not published here.
There is no public change log
The live WINEP spreadsheet is internal, and there is no versioned public comparison or published reasons when a measure is re-dated or dropped. The only way to hold slippage to account is to archive every annual release and diff it yourself.
The 2027 pressure point
Most investigations must complete by 30 April 2027 to feed the 2030–35 programme. That date — not 2030 — is the one to hold: an investigation that slips past it cannot shape the next round of funded schemes.