Why it keeps happening
Three things we can measure in the data. None of them proves a cause on its own, but each points at a different kind of infrastructure problem.
A discharge in dry weather is not an exceptional circumstance, so it is not permitted on any reading of regulation 4.
See the 13 →A strong signal, not a finding. We cannot see whether flow is transferred to another works for treatment, and the permitted figure is not always published.
See the 0 →Rainfall across the catchment does not explain a discharge that an overflow's own treatment works did not share.
See the 25 →Where the indicators concentrate
| Overflow | Hours | Dry | What it points to | Verdict |
|---|---|---|---|---|
| Shrewton Storm Tank | 2,674 | 658 | High spill frequency | No action |
| Hurdcott Storm Tank | 2,588 | 2874 | High spill frequency | No action |
| Allington Old Inn | 1,971 | 33 | Very long spills | No action |
| Barford St Martin Burcombe Storm Tank | 1,541 | 226 | High spill frequency | No action |
| Coate Spaniels Bridge | 1,077 | 20 | Very long spills | No action |
| Fovant Storm Tank | 1,010 | 980 | High spill frequency | No action |
| Tilshead Camp Road | 684 | 33 | Dry spilling | No action |
| Collingbourne Ducis | 13 | 92 | Dry spilling | No action |
| Hanging Langford | 0 | 207 | Dry spilling | No action |
| Pewsey Salisbury Road Storm Tank | 731 | 20 | Dry spilling | No action |
Hours are the last full year; dry spills are since 2020. Verdict is whether a measure is linked to the overflow — see the gaps.
What this analysis cannot see
These indicators are measured from spill timing and rainfall alone. They cannot see misconnections, the quality of effluent from a works that is running normally, flow transferred between works for treatment, a company's maintenance history, or the periods when a monitor was offline. Because a quiet monitor records nothing, every count here is a floor, not a total.