EA sampling point

Clayton House (Pond Inlet) B/H, Ellesbor

Sampled by the Environment Agency on 18 visits from 2021 to 2026.

Phosphate

2021–2026: avg 0.012 · max 0.020 mg/l
00.050.10.150.2202220232024202520262021-09-14: 0.015 mg/l2021-10-12: 0.016 mg/l2022-01-27: 0.013 mg/l2022-11-10: 0.016 mg/l2023-01-25: 0.016 mg/l2023-07-17: 0.012 mg/l2023-10-06: 0.011 mg/l2024-01-10: below 0.01 mg/l2024-07-16: below 0.01 mg/l2024-10-16: below 0.01 mg/l2025-01-10: 0.012 mg/l2025-05-22: 0.018 mg/l2025-10-23: below 0.01 mg/l2026-01-22: 0.015 mg/l2026-05-28: below 0.01 mg/l2026-07-31: 0.02 mg/l
High ≤ 0.036Good ≤ 0.069Moderate ≤ 0.173Poor ≤ 1.003Bad > 1.003

Ammonia

2021–2026: avg 0.019 · max 0.086 mg/l
00.20.40.6202220232024202520262021-09-14: below 0.03 mg/l2021-10-12: below 0.03 mg/l2022-01-27: below 0.03 mg/l2022-11-10: below 0.03 mg/l2023-01-25: below 0.03 mg/l2023-07-17: below 0.03 mg/l2023-10-06: below 0.03 mg/l2024-01-10: below 0.03 mg/l2024-07-16: below 0.03 mg/l2024-10-16: below 0.03 mg/l2025-01-10: below 0.03 mg/l2025-05-22: below 0.03 mg/l2025-10-23: below 0.03 mg/l2026-01-22: below 0.03 mg/l2026-05-28: 0.086 mg/l2026-07-31: below 0.03 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2021–2026: avg 87 · min 57 % saturation
6080100120202220232024202520262021-09-14: 94.5 % saturation2021-10-12: 96 % saturation2022-01-27: 65.2 % saturation2022-11-10: 99.5 % saturation2023-01-25: 90.7 % saturation2023-07-17: 92.6 % saturation2023-10-06: 91.4 % saturation2024-01-10: 95.1 % saturation2024-05-22: 57.2 % saturation2024-07-16: 93.6 % saturation2024-10-16: 95.9 % saturation2025-01-10: 94.7 % saturation2025-05-22: 92.3 % saturation2025-10-23: 77.8 % saturation2026-01-22: 95 % saturation2026-05-28: 78.1 % saturation2026-07-31: 73.9 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

4.1–14.9 °C

Warm water holds less oxygen. There is no river standard for temperature here.

05101520202220232024202520262021-09-14: 10.8 °C2021-10-12: 9.9 °C2022-01-27: 4.7 °C2022-11-10: 11.7 °C2023-01-25: 8.9 °C2023-07-17: 12.3 °C2023-10-06: 11 °C2024-01-10: 4.1 °C2024-05-22: 13.3 °C2024-07-16: 11.6 °C2024-10-16: 12 °C2025-01-10: 8 °C2025-05-22: 10.3 °C2025-10-23: 9.8 °C2026-01-22: 10.2 °C2026-05-28: 14.9 °C2026-07-31: 11.1 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: Conductivity at 25 C (MICROSIEMENS PER CENTIMETRE)

EA sampling point TH-PGWU1954 · Misbourne · 533 readings of 125 tests since 2021.

DateResultUnitSample
2026-07-31 09:01546MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-05-28 10:07419MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-01-22 09:17602MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-10-23 09:14287MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-05-22 11:57558MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-01-10 12:09559MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-10-16 13:18429MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-07-16 13:47543MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-05-22 09:04572MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-01-10 12:18378MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-10-06 12:22559MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-07-17 11:34548MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-01-25 09:17578MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2022-11-10 12:55550MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2022-01-27 14:29573MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2021-10-12 09:30551MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2021-09-14 09:58545MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)

Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the River Colne.