NRW sampling point

Afon Hesbin @ Pont Eyarth-Uchaf

Sampled by Natural Resources Wales on 2 visits in 2026.

Phosphate

2026: avg 0.031 · max 0.041 mg/l
00.050.10.150.22026-04-14: 0.021 mg/l2026-08-06: 0.0409 mg/l
High ≤ 0.036Good ≤ 0.069Moderate ≤ 0.173Poor ≤ 1.003Bad > 1.003

Ammonia

2026: avg 0.024 · max 0.025 mg/l
00.20.40.62026-04-14: 0.0229 mg/l2026-08-06: 0.025 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2026: avg 107 · min 100 % saturation
60801001202026-04-14: 100.4 % saturation2026-08-06: 114.4 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

8.5–14.3 °C

Warm water holds less oxygen. There is no river standard for temperature here.

051015202026-04-14: 8.5 °C2026-08-06: 14.3 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative:Natural Resources Wales’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: Alkalinity to pH 4.5 as CaCO3 (mg/l)

NRW sampling point S1328 · 20 readings of 10 tests since 2026.

DateResultUnitSample
2026-08-06 14:54191mg/lRIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-04-14 11:30150mg/lRIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)

Source: Natural Resources Wales Open Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the River Clwyd.

Afon Hesbin @ Pont Eyarth-Uchaf: NRW water tests — Afon Clwyd / River Clwyd Data