Who is fixing it

What the regulator requires

A measure is a specific action the regulator requires the water company to take at a named site — to investigate a problem, keep monitoring it, or physically fix it — each with a completion date. These are the legally binding measures on record for this catchment: what each requires, and what to watch.

These measures are legally binding. Each one is a dated, site-specific requirement the company must deliver.

The National Environment Programme is how Natural Resources Wales turns statutory duties into named obligations at named sites, with a completion date attached. Where a measure requires a physical upgrade, NRW writes the result into the site's environmental permit — and from that point the requirement is criminally enforceable.

The measure itself is public. What is not published is the water company's action to comply with it — its delivery is reported to the regulator and scored, but the underlying work, and whether a measure has actually resolved the problem on the ground, is not on the public record. What to watch is slippage: a measure can be re-dated or re-scoped, and until the permit is varied the obligation has not changed.

What the types mean

Improvement

A physical upgrade — bigger storage, better treatment, more capacity. This is the only type that actually fixes the problem on the ground.

Investigation

A study of the cause. It produces a report, not a repair — an investigation must lead to an improvement before anything changes.

Monitoring

Installing or running instruments to measure the problem. Necessary evidence, but on its own it fixes nothing — it too has to be followed by an improvement.

So an overflow whose only measures are investigations or monitoring is being looked at, not yet fixed. On the gaps page, only a measure that is still active counts as action — a measure completed while the overflow is still failing does not.

83
Measures in this catchment
NEP, current record
71
Still active
not yet past their date
12
Assumed complete
completion date has passed
33
Are physical improvements
the rest investigate or monitor
ReferenceDriverTypeWhat it requiresStatusAttached to
DCWW100118a · 5e8af028W_U_MON3Monitoring
MCERTS certified Flow Passed Forward (FPF) overflow operation monitoring at WwTW or last in line Sewage Pumping Station overflows
WQ
BALA WWTW
Complete 2025-26Bala WwTW Storm Overflow
DCWW100143a · 533b288dW_U_MON3Monitoring
MCERTS certified Flow Passed Forward (FPF) overflow operation monitoring at WwTW or last in line Sewage Pumping Station overflows
WQ
BRYNREFAIL STW
Complete 2025-26Cefn Mawr WwTW Storm Overflow
DCWW100073a · 020cd1c6W_U_MON3Monitoring
MCERTS certified Flow Passed Forward (FPF) overflow operation monitoring at WwTW or last in line Sewage Pumping Station overflows
WQ
CARWAY WWTW CARWAY CARMS
Complete 2025-26Church Street Llanuwchllyn Storm Overflow
DCWW100158a · 78e43437W_U_MON3Monitoring
MCERTS certified Flow Passed Forward (FPF) overflow operation monitoring at WwTW or last in line Sewage Pumping Station overflows
WQ
CEFN MAWR STW HEOL BERWYN CEFN MAWR
Complete 2025-26Cefn Mawr WwTW Storm Overflow
DCWW100161a · 453c5d85W_U_MON3Monitoring
MCERTS certified Flow Passed Forward (FPF) overflow operation monitoring at WwTW or last in line Sewage Pumping Station overflows
WQ
CERRIGYDRUDION STW
Complete 2025-26Cerrigydrudion WwTW Storm Overflow
DCWW100169a · abf97361W_U_MON3Monitoring
MCERTS certified Flow Passed Forward (FPF) overflow operation monitoring at WwTW or last in line Sewage Pumping Station overflows
WQ
CORWEN WWTW FINAL EFFLUENT
Complete 2025-26Corwen WwTW Storm Overflow
DCWW100100a · cad0cc79W_U_MON3Monitoring
MCERTS certified Flow Passed Forward (FPF) overflow operation monitoring at WwTW or last in line Sewage Pumping Station overflows
WQ
CYNWYD STW FINAL EFFLUENT
Complete 2025-26Cynwyd WwTW Storm Overflow
DCWW100196a · 32a2fe96W_U_MON3Monitoring
MCERTS certified Flow Passed Forward (FPF) overflow operation monitoring at WwTW or last in line Sewage Pumping Station overflows
WQ
DOLYWERN STW
Complete 2025-26Dolywern WwTW Storm Overflow
DCWW100218a · d953e684W_U_MON3Monitoring
MCERTS certified Flow Passed Forward (FPF) overflow operation monitoring at WwTW or last in line Sewage Pumping Station overflows
WQ
GLYNCEIRIOG STW
Complete 2025-26Y Gamer Glyn Ceiriog Storm Overflow
DCWW100251a · afe1e510W_U_MON3Monitoring
MCERTS certified Flow Passed Forward (FPF) overflow operation monitoring at WwTW or last in line Sewage Pumping Station overflows
WQ
LLANDRILLO STW
Complete 2025-26Llandrillo Storm Overflow
DCWW100273a · 05bdee1aW_U_MON3Monitoring
MCERTS certified Flow Passed Forward (FPF) overflow operation monitoring at WwTW or last in line Sewage Pumping Station overflows
WQ
LLANGOLLEN WWTW
Complete 2025-26Llangollen WwTW Storm Overflow
DCWW100088a · d8746a64W_U_MON3Monitoring
MCERTS certified Flow Passed Forward (FPF) overflow operation monitoring at WwTW or last in line Sewage Pumping Station overflows
WQ
LLANUWCHLLYN STW LLANUWCHLLYN
Complete 2025-26Church Street Llanuwchllyn Storm Overflow
DCWW101598a · 97fc167aW_WFD_PG_IMP4Improvement
Implementation of actions to achieve good status at a waterbody and / or site level due to Phosphorus relating to Reasons for Not Achieving Good (RNAGs) identified against water company assets or activities and phosphorus status of the waterbody.
WQ
CERRIGYDRUDION (SWK)
Due 2026-27CERRIGYDRUDION
DCWW102138a · f4f2acd9W_U_O_INV1Investigation
Investigation to classify a storm overflow in ''high priority locations'' in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
CHIRK BANK PS
Due 2026-27Chirk Bank Storm Overflow
DCWW102135a · e83d70f4W_U_O_INV1Investigation
Investigation to classify a storm overflow in ''high priority locations'' in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
DOLYWERN (NR CHIRK)
Due 2026-27North West of Bro-Ddewi Dolywern Storm Overflow
DCWW102131a · 679a2929W_U_O_INV1Investigation
Investigation to classify a storm overflow in ''high priority locations'' in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
DOLYWERN (NR CHIRK) STW
Due 2026-27Dolywern WwTW Storm Overflow
UU100001a · 7f3370d3W_EEL_IMP1Improvement
Implementation of actions to improve abstractions and outfalls to prevent the entrainment of eels and to address barriers to passage of eels
Eel
Horseshoe falls abstraction - eel screening
Due 2026-27Water body only
DCWW102130a · 6b7fd8d3W_U_O_INV1Investigation
Investigation to classify a storm overflow in ''high priority locations'' in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
LLANGOLLEN STW
Due 2026-27Llangollen WwTW Storm Overflow
DCWW102134a · 9a07ae24W_U_O_INV1Investigation
Investigation to classify a storm overflow in ''high priority locations'' in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
LLANGOLLEN Tannery CSO
Due 2026-27Llangollen Queen Street Storm Overflow
DCWW102181a · 54bbfd8bW_U_O_INV1Investigation
Investigation to classify a storm overflow in ''high priority locations'' in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
NEW ROAD WREXHAM
Due 2026-27New Road Wrexham Storm Overflow
DCWW102133a · 4b864e9bW_U_O_INV1Investigation
Investigation to classify a storm overflow in ''high priority locations'' in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
PARK AVENUE CSO
Due 2026-27Park Avenue Storm Overflow
DCWW102007a · 786a824cW_U_O_IMP1Improvement
Action to implement improvements to overflows classified as Unsatisfactory
WQ
Afon Eitha CSO
Due 2029-30Pont-Yr-Afon Field Storm Overflow
DCWW101582a · afe2d289W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
BERWYN STREET CSO
Due 2029-30Berwyn Street Storm Overflow
DCWW101694a · 9253d36aW_HR_P_ND_IMP1Improvement
Implementation of actions to prevent deterioration to achieve the 5mg/l “back stop” limit in a Special Area of Conservation (SAC) river catchment, where the waterbody meets the Phosphate standard but where there is evidence of a risk of failure.
WQ
BETWS GWERFIL GOCH STW
Due 2029-30Water body only
DCWW101701a · e9142b4aW_HR_P_ND_IMP1Improvement
Implementation of actions to prevent deterioration to achieve the 5mg/l “back stop” limit in a Special Area of Conservation (SAC) river catchment, where the waterbody meets the Phosphate standard but where there is evidence of a risk of failure.
WQ
BRYNEGLWYS STW
Due 2029-30Water body only
DCWW101707a · 2e6013a4W_HR_P_ND_IMP1Improvement
Implementation of actions to prevent deterioration to achieve the 5mg/l “back stop” limit in a Special Area of Conservation (SAC) river catchment, where the waterbody meets the Phosphate standard but where there is evidence of a risk of failure.
WQ
CARROG SEWAGE TREATMENT WORKS
Due 2029-30Water body only
DCWW101707b · a78092dfW_HR_AMM_T_IMP1Improvement
Operational costs relating to Ammonia permit condition Implementation of actions to meet Total Ammonia standards at required water company assets to address observed and/or predicted failure of Total Ammonia standards in Special Area of Conservation (SAC) river catchments.
WQ
Carrog Wastewater Treatment Works
Due 2029-30Water body only
DCWW101849a · 8e415b50W_HR_P_ND_IMP1Improvement
Implementation of actions to prevent deterioration to achieve the 5mg/l “back stop” limit in a Special Area of Conservation (SAC) river catchment, where the waterbody meets the Phosphate standard but where there is evidence of a risk of failure.
WQ
CEFN BRITH STW
Due 2029-30Water body only
DCWW101418a · 142894c2W_U_MON6Monitoring
MCERTS certified monitoring (EDM event duration monitor) of emergency overflow operation on network pumping stations
WQ
CEFN PS
Due 2029-30Cefn Storm Overflow
DCWW100660a · 0df80c6aW_U_IMP6Improvement
Increasing storm tank capacity to provide adequate settlement and detention at WwTWs that were identified in PR19 and were subsequently deferred until PR24 with the written agreement of NRW
WQ
CEFN-MAWR
Due 2029-30Cefn Mawr WwTW Storm Overflow
DCWW102825a · 89f7491dW_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
CHIRK CHAPEL LANE/LLOYDS LANE CSO
Due 2029-30Offa Street Chirk Storm Overflow
DCWW102485a · 40e757a3W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
CHIRK O/S 24 OFFA STREET
Due 2029-30Chapel Lane and Lloyds Lane Chirk Storm Overflow
DCWW101272a · b0edc539W_U_MON6Monitoring
MCERTS certified monitoring (EDM event duration monitor) of emergency overflow operation on network pumping stations
WQ
CHIRK SEWAGE PUMPING STATION
Due 2029-30Offa Street Chirk Storm Overflow
DCWW101384a · f476a255W_U_MON6Monitoring
MCERTS certified monitoring (EDM event duration monitor) of emergency overflow operation on network pumping stations
WQ
CHIRK STATION INDUSTRIAL SITE
Due 2029-30Offa Street Chirk Storm Overflow
DCWW102476a · a485c630W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
CHIRK STORM TANKS SCREENED STORM
Due 2029-30Offa Street Chirk Storm Overflow
DCWW102475a · 99a67febW_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
CHIRK STORM TANKS SETTLED STORM
Due 2029-30Offa Street Chirk Storm Overflow
DCWW102845a · ea9a69a3W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
CORWEN CLAWDD PONCEFN PS
Due 2029-30Corwen Clawdd Poncefn Storm Overflow
DCWW101426a · 7be50255W_U_MON6Monitoring
MCERTS certified monitoring (EDM event duration monitor) of emergency overflow operation on network pumping stations
WQ
CORWEN CLAWDD PONCEN PS
Due 2029-30Corwen Clawdd Poncefn Storm Overflow
DCWW101582a · fc6ae0a0W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
Corwen Corner Station Yard CSO
Due 2029-30Northern Terrace Corwen Storm Overflow
DCWW102005a · 75b03124W_U_O_IMP1Improvement
Action to implement improvements to overflows classified as Unsatisfactory
WQ
Corwen WwTW
Due 2029-30Corwen WwTW Storm Overflow
DCWW102855b · f8b8559aW_HR_AMM_T_IMP1Improvement
Operational costs relating to Ammonia permit condition Implementation of actions to meet Total Ammonia standards at required water company assets to address observed and/or predicted failure of Total Ammonia standards in Special Area of Conservation (SAC) river catchments.
WQ
CORWEN WWTW FINAL EFFLUENT
Due 2029-30CORWEN WWTW STW
DCWW101720a · ce7ad5abW_HR_P_ND_IMP1Improvement
Implementation of actions to prevent deterioration to achieve the 5mg/l “back stop” limit in a Special Area of Conservation (SAC) river catchment, where the waterbody meets the Phosphate standard but where there is evidence of a risk of failure.
WQ
CYNWYD STW
Due 2029-30CYNWYD
DCWW101720b · 61e1e215W_HR_AMM_T_IMP1Improvement
Operational costs relating to Ammonia permit condition Implementation of actions to meet Total Ammonia standards at required water company assets to address observed and/or predicted failure of Total Ammonia standards in Special Area of Conservation (SAC) river catchments.
WQ
CYNWYD STW FINAL EFFLUENT
Due 2029-30CYNWYD
DCWW101722b · 463138daW_HR_AMM_T_IMP1Improvement
Operational costs relating to Ammonia permit condition Implementation of actions to meet Total Ammonia standards at required water company assets to address observed and/or predicted failure of Total Ammonia standards in Special Area of Conservation (SAC) river catchments.
WQ
DOLYWERN STW
Due 2029-30Water body only
DCWW101725b · ded73650W_HR_AMM_T_IMP1Improvement
Ammonia reduction to meet numeric permit limit Implementation of actions to meet Total Ammonia standards at required water company assets to address observed and/or predicted failure of Total Ammonia standards in Special Area of Conservation (SAC) river catchments.
WQ
FRONCYSYLLTE STW
Due 2029-30CEFN MAWR STW HEOL BERWYN CEFN MAWR STW
DCWW100669a · 1cd421fcW_U_IMP6Improvement
Increasing storm tank capacity to provide adequate settlement and detention at WwTWs that were identified in PR19 and were subsequently deferred until PR24 with the written agreement of NRW
WQ
GLYN CEIRIOG
Due 2029-30Y Gamer Glyn Ceiriog Storm Overflow
DCWW102006a · 0d8f347bW_U_O_IMP1Improvement
Action to implement improvements to overflows classified as Unsatisfactory
WQ
GLYN CEIRIOG Y GAMMER
Due 2029-30Y Gamer Glyn Ceiriog Storm Overflow
DCWW101728b · e1e52290W_HR_AMM_T_IMP1Improvement
Operational costs relating to Ammonia permit condition Implementation of actions to meet Total Ammonia standards at required water company assets to address observed and/or predicted failure of Total Ammonia standards in Special Area of Conservation (SAC) river catchments.
WQ
GLYNCEIRIOG STW
Due 2029-30Water body only
DCWW101729a · c140ea09W_HR_P_ND_IMP1Improvement
Implementation of actions to prevent deterioration to achieve the 5mg/l “back stop” limit in a Special Area of Conservation (SAC) river catchment, where the waterbody meets the Phosphate standard but where there is evidence of a risk of failure.
WQ
GLYNDYFRDWY (NR LLANGOLLEN) STW
Due 2029-30Water body only
DCWW102847a · 878b3754W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
GWYDDELWERN PS SCREENED STORM
Due 2029-30Gwydelwern Storm Overflow
DCWW101438a · 5acc931eW_U_MON6Monitoring
MCERTS certified monitoring (EDM event duration monitor) of emergency overflow operation on network pumping stations
WQ
GWYDDELWERN SEWAGE PUMPING STATION
Due 2029-30Gwydelwern Storm Overflow
DCWW101732a · 0c4dea80W_HR_P_ND_IMP1Improvement
Implementation of actions to prevent deterioration to achieve the 5mg/l “back stop” limit in a Special Area of Conservation (SAC) river catchment, where the waterbody meets the Phosphate standard but where there is evidence of a risk of failure.
WQ
HALTON STW
Due 2029-30Water body only
DCWW101732b · 2135139dW_HR_AMM_T_IMP1Improvement
Operational costs relating to Ammonia permit condition Implementation of actions to meet Total Ammonia standards at required water company assets to address observed and/or predicted failure of Total Ammonia standards in Special Area of Conservation (SAC) river catchments.
WQ
HALTON Wastewater Treatment Works
Due 2029-30Water body only
UU100003a · 0bf058c9W_DrWPA_NDIMP1Improvement
Implementation of cost effective actions through a catchment scheme to prevent deterioration (or improve following a deterioration) in water quality (ground and surface water) to avoid an increase in the level of water purification treatment.
DrWPA
Huntington and Sutton Hall (River Dee Turbidity)
Due 2029-30Water body only
DCWW101737a · 52f5ff08W_HR_P_ND_IMP1Improvement
Implementation of actions to prevent deterioration to achieve the 5mg/l “back stop” limit in a Special Area of Conservation (SAC) river catchment, where the waterbody meets the Phosphate standard but where there is evidence of a risk of failure. for P and Ammonia
WQ
LLANDDERFEL SEWAGE TREATMENT WORKS
Due 2029-30Water body only
DCWW102494a · cf16cf16W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
LLANDRILLO (SW OF LLANGOLLEN) SDW PS A
Due 2029-30Llandrillo Storm Overflow
DCWW101738a · 52d2e4a5W_HR_P_ND_IMP1Improvement
Implementation of actions to prevent deterioration to achieve the 5mg/l “back stop” limit in a Special Area of Conservation (SAC) river catchment, where the waterbody meets the Phosphate standard but where there is evidence of a risk of failure.
WQ
LLANDRILLO STW
Due 2029-30Water body only
DCWW101738b · 69b41165W_HR_AMM_T_IMP1Improvement
Operational costs relating to Ammonia permit condition Implementation of actions to meet Total Ammonia standards at required water company assets to address observed and/or predicted failure of Total Ammonia standards in Special Area of Conservation (SAC) river catchments.
WQ
LLANDRILLO STW
Due 2029-30Water body only
DCWW101853a · 30f5d7e7W_HR_P_ND_IMP1Improvement
Implementation of actions to prevent deterioration to achieve the 5mg/l “back stop” limit in a Special Area of Conservation (SAC) river catchment, where the waterbody meets the Phosphate standard but where there is evidence of a risk of failure.
WQ
LLANFIHANGEL GLYN MYFYR STW
Due 2029-30Water body only
DCWW100674a · dc8fe5c1W_U_IMP6Improvement
Increasing storm tank capacity to provide adequate settlement and detention at WwTWs that were identified in PR19 and were subsequently deferred until PR24 with the written agreement of NRW
WQ
LLANGOLLEN
Due 2029-30Llangollen WwTW Storm Overflow
DCWW101582a · f77e0d13W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
Llangollen Chruch St CSO
Due 2029-30Llangollen Church Street Storm Overflow
DCWW101582a · 8113329fW_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
Llangollen East St CSO
Due 2029-30Llangollen East Street Storm Overflow
DCWW101353a · 2793ac16W_U_MON6Monitoring
MCERTS certified monitoring (EDM event duration monitor) of emergency overflow operation on network pumping stations
WQ
LLANGOLLEN PUMP STATION (STW CSO)
Due 2029-30Llangollen WwTW Storm Overflow
DCWW101582a · f00e41b1W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
Llangollen Riverside Park Printing Works CSO
Due 2029-30Llangollen Riverside Park Storm Overflow
DCWW101582a · b300b3e9W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
Llangollen Victoria Prom Riverside CSO
Due 2029-30Llangollen Victoria Prom Storm Overflow
DCWW100088b · 382985e6W_HR_AMM_T_IMP1Improvement
Operational costs relating to Ammonia permit condition Implementation of actions to meet Total Ammonia standards at required water company assets to address observed and/or predicted failure of Total Ammonia standards in Special Area of Conservation (SAC) river catchments.
WQ
LLANUWCHLLYN STW
Due 2029-30LLANUWCHLLYN
DCWW101855a · d9907862W_HR_P_ND_IMP1Improvement
Implementation of actions to prevent deterioration to achieve the 5mg/l “back stop” limit in a Special Area of Conservation (SAC) river catchment, where the waterbody meets the Phosphate standard but where there is evidence of a risk of failure.
WQ
LLIDIART ANNIE SEWAGE TREATMENT WORKS
Due 2029-30Water body only
DCWW101407a · 921892c0W_U_MON6Monitoring
MCERTS certified monitoring (EDM event duration monitor) of emergency overflow operation on network pumping stations
WQ
NEWBRIDGE PS, NR WREXHAM
Due 2029-30Next to Bridge Newbridge Overflow
DCWW101582a · 94f10607W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
Newbridge SPS
Due 2029-30Next to Bridge Newbridge Overflow
DCWW101741a · b03feceaW_HR_P_ND_IMP1Improvement
Implementation of actions to prevent deterioration to achieve the 5mg/l “back stop” limit in a Special Area of Conservation (SAC) river catchment, where the waterbody meets the Phosphate standard but where there is evidence of a risk of failure. for P and Ammonia
WQ
PANDY SEWAGE TREATMENT WORKS
Due 2029-30Water body only
DCWW101408a · fe5f1943W_U_MON6Monitoring
MCERTS certified monitoring (EDM event duration monitor) of emergency overflow operation on network pumping stations
WQ
Pen y Cae PS CSO, Afoneitha road, Wrexham LL14 2PF
Due 2029-30Penycae Storm Overflow
DCWW101857a · 4dd4ca36W_HR_P_ND_IMP1Improvement
Implementation of actions to prevent deterioration to achieve the 5mg/l “back stop” limit in a Special Area of Conservation (SAC) river catchment, where the waterbody meets the Phosphate standard but where there is evidence of a risk of failure.
WQ
PENTRELLYNCYMMER STW
Due 2029-30Water body only
DCWW101582a · 1e37be25W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
Penycae SPS
Due 2029-30Penycae Storm Overflow
DCWW101582a · 93d0de00W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
Penycae West End School Field Land CSO Afon Eitha, Penycae, Pen-y-cae, Wrexham
Due 2029-30Penycae Storm Overflow
DCWW102842a · 97f8d939W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
RHOSLLANERCHRUGOG ABERDERFYN
Due 2029-30Trofryn Rhosllanerchrugog Overflow
DCWW101582a · d9aed530W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
Royal Hotel CSO
Due 2029-30Bridge Street Storm Overflow No1
DCWW102827a · 45208273W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
Ruabon CSO Ruabon New Hall road
Due 2029-30Paddock Row Ruabon Storm Overflow
DCWW101582a · 9e86b5daW_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
Ruabon Paddock Row CSO
Due 2029-30Paddock Row Ruabon Storm Overflow
DCWW101415a · cb353726W_U_MON6Monitoring
MCERTS certified monitoring (EDM event duration monitor) of emergency overflow operation on network pumping stations
WQ
RUABON PS
Due 2029-30Paddock Row Ruabon Storm Overflow No2
DCWW102008a · a15f2fe7W_U_O_IMP1Improvement
Action to implement improvements to overflows classified as Unsatisfactory
WQ
Ruabon SPS
Due 2029-30Paddock Row Ruabon Storm Overflow No2
DCWW102002a · cc63878fW_U_O_IMP1Improvement
Action to implement improvements to overflows classified as Unsatisfactory
WQ
The Eagles CSO, Llanwchllyn
Due 2029-30Church Street Llanuwchllyn Storm Overflow
DCWW101582a · c3081cd2W_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
WEST STREET CSO Llangollen, Denbighshire
Due 2029-30Llangollen West Street Storm Overflow
DCWW102813a · 813d15cfW_U_O_INV1Investigation
Investigation to classify a storm overflow in accordance with NRW’s storm overflow classification guidance where assessment of the asset has not previously been captured by other programmes
WQ
WREXHAM PLAS MADOC REAR HAMPDEN WAY
Due 2029-30South of Hampden Way Wrexham Storm Overflow

83 of 83 measures shown. A measure whose completion date has passed is shown as Complete; the water company's actual delivery against it is reported to the regulator but not published here.

There is no public change log

NRW publishes the NEP as an open map layer, but there is no versioned public comparison or published reasons when a measure is re-dated or dropped. The only way to hold slippage to account is to archive every annual release and diff it yourself.

The 2027 pressure point

Most investigations must complete by 30 April 2027 to feed the 2030–35 programme. That date — not 2030 — is the one to hold: an investigation that slips past it cannot shape the next round of funded schemes.