Why it keeps happening
Three things we can measure in the data. None of them proves a cause on its own, but each points at a different kind of infrastructure problem.
A discharge in dry weather is not an exceptional circumstance, so it is not permitted on any reading of regulation 4.
See the 16 →A strong signal, not a finding. We cannot see whether flow is transferred to another works for treatment, and the permitted figure is not always published.
See the 0 →Rainfall across the catchment does not explain a discharge that an overflow's own treatment works did not share.
See the 29 →Where the indicators concentrate
| Overflow | Hours | Dry | What it points to | Verdict |
|---|---|---|---|---|
| Shebbear STWSSO | 1,250 | 36 | High spill frequency | No action |
| Horns Cross STWSO | 1,969 | 50 | Very long spills | No action |
| Roborough STWSSO | 844 | 200 | High spill frequency | No action |
| Sheepwash STWSO | 1,515 | 14 | Very long spills | No action |
| Hill Barton STW, OkehamptonSSO | 1,089 | 10 | Very long spills | No action |
| Merton STWSO | 1,016 | 13 | Very long spills | No action |
| Bradworthy STWSSO | 541 | 6 | High spill frequency | No action |
| Folly Gate STWSSO | 2,580 | 15 | Very long spills | No action |
| Highampton STW, HatherleighSSO | 1,323 | 109 | Very long spills | No action |
| Buckland Brewer STWSO | 1,129 | 18 | Very long spills | No action |
Hours are the last full year; dry spills are since 2020. Verdict is whether a measure is linked to the overflow — see the gaps.
What this analysis cannot see
These indicators are measured from spill timing and rainfall alone. They cannot see misconnections, the quality of effluent from a works that is running normally, flow transferred between works for treatment, a company's maintenance history, or the periods when a monitor was offline. Because a quiet monitor records nothing, every count here is a floor, not a total.