← Cirencester STW

Spill evidence · River Hub

Cirencester STW

Storm overflow · TWL00102 · feeds CIRENCESTER, CIRENCESTER, GLOS STW"
Dry spill

Evidence strength

Low confidence
  • ✓ Dry on the EA 1-day window
  • ✓ Monitor 100% operational that year
  • ⚠ Short discharge (<1 h) — weaker signal
  • ⚠ Rain gauge ~46 km away — less representative

The discharge

Spill day
Saturday, 28 December 2024
Started
28 Dec 2024, 15:00
Ended
28 Dec 2024, 15:45
Duration
45 minutes
Receiving water
Cerney Wick Brook (source to Thames)
Parish
Somerford Keynes

Rainfall evidence

Daily rainfall at the matched gauge (Abingdon) for the spill day and the days before. A spill is dry when every day in the window is ≤ 0.25 mm.

1-day window: Dry spill3-day window: Wet weather4-day window: Wet weather
DateRainfall
28/12/2024 (spill day)0.19 mmdry
27/12/20240.24 mmdry
26/12/20240.23 mmdry
25/12/20240.48 mmrain
24/12/20240.14 mmdry

River flow that day: 5.233 m³/s. Verify at the EA rainfall station.

Gauge proximity

Outlet (red) vs matched rain gauge (blue), 45.7 km apart. Closer means the rainfall reading is more representative of the overflow.

Loading map…

Severity & context

Bathing water
Not Applicable
Shellfish water
Not Applicable
EA annual return (2024)
236 counted spills · 4460 h total
Monitor uptime (2024)
100% operational
Method & provenance. Dry/wet classification is decided by rainfall at the nearest EA gauge — ≤ 0.25 mm on the spill day and each preceding day of the window (how we classify). Spill data: Environment Agency EDM (outlet TWL00102). Rainfall: EA Hydrology gauge fe3efb87-062c-4880-9dc3-7dd8f335a6d1. A dry spill is precautionary evidence of a likely fault, not proof of an offence — we test the rainfall, not the works' flow. Generated by River Thames Data.