EA sampling point

River Enborne Below Yew Tree Farm

Sampled by the Environment Agency on 10 visits in 2026. Phosphate, ammonia and dissolved oxygen are good or better. Averages are over 2023–2025.

Phosphate

2026: avg 0.045 · max 0.120 mg/l

Band, 2023–2025 average: 0.059 · Good

00.050.10.150.22026-01-27: 0.12 mg/l2026-02-25: 0.037 mg/l2026-03-16: 0.027 mg/l2026-04-30: 0.027 mg/l2026-05-18: 0.029 mg/l2026-06-16: 0.055 mg/l2026-07-29: 0.075 mg/l2026-09-04: 0.045 mg/l2026-10-07: 0.034 mg/l2026-11-12: below 0.01 mg/l
High ≤ 0.036Good ≤ 0.069Moderate ≤ 0.173Poor ≤ 1.003Bad > 1.003

Ammonia

2026: avg 0.015 · max 0.015 mg/l

Band, 2023–2025 average: 0.023 · High

00.20.40.62026-01-27: below 0.03 mg/l2026-02-25: below 0.03 mg/l2026-03-16: below 0.03 mg/l2026-04-30: below 0.03 mg/l2026-05-18: below 0.03 mg/l2026-06-16: below 0.03 mg/l2026-07-29: below 0.03 mg/l2026-09-04: below 0.03 mg/l2026-10-07: below 0.03 mg/l2026-11-12: below 0.03 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2026: avg 87 · min 68 % saturation

Band, 2023–2025 average: 89 · High

60801001202026-01-27: 99 % saturation2026-02-25: 93.7 % saturation2026-03-16: 97.3 % saturation2026-04-30: 93.6 % saturation2026-05-18: 93.9 % saturation2026-06-16: 91.1 % saturation2026-07-29: 67.8 % saturation2026-09-04: 72.3 % saturation2026-10-07: 69.1 % saturation2026-11-12: 89.1 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

7.3–19.1 °C

Warm water holds less oxygen. There is no river standard for temperature here.

01020302026-01-27: 7.5 °C2026-02-25: 9.2 °C2026-03-16: 8.2 °C2026-04-30: 9 °C2026-05-18: 10.6 °C2026-06-16: 16 °C2026-07-29: 19.1 °C2026-09-04: 17.7 °C2026-10-07: 14 °C2026-11-12: 7.3 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: Conductivity at 25 C (MICROSIEMENS PER CENTIMETRE)

EA sampling point TH-PKER0295 · Enborne (Source to downstream A34) · 514 readings of 60 tests since 2023.

DateResultUnitSample
2026-11-12 12:31435MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-10-07 11:36321MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-09-04 11:49252MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-07-29 12:47250MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-06-16 11:37260MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-05-18 11:23254MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-04-30 08:50254MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-03-16 11:40225MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-02-25 09:23208MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-01-27 11:42135MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-12-02 10:15227MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-11-11 10:37333MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-10-27 11:08381MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-09-26 12:57315MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-08-21 08:11275MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-07-21 11:41313MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-06-25 11:14287MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-05-14 10:58285MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-04-23 09:58296MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-03-19 11:32249MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-02-18 12:22238MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-01-28 13:35191MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-12-13 12:09256MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-11-25 10:14169MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-10-30 12:25257MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-10-15 13:24227MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-08-22 08:00269MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-07-19 11:21293MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-06-24 14:05446MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-03-08 12:19242MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-02-02 10:59253MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-01-11 13:46242MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-12-05 08:32216MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-11-15 09:58230MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-10-31 08:45245MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-09-01 11:10260MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-08-07 14:36261MICROSIEMENS PER CENTIMETRERIVER / RUNNING SURFACE WATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)

Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the River Test.