EA sampling point

Ruda Holiday Park-New Borehole

Sampled by the Environment Agency on 2 visits in 2026.

Phosphate

2026: avg 0.009 · max 0.013 mg/l
00.050.10.150.22026-01-20: below 0.01 mg/l2026-10-05: 0.013 mg/l
High ≤ 0.036Good ≤ 0.069Moderate ≤ 0.173Poor ≤ 1.003Bad > 1.003

Ammonia

2026: avg 0.015 · max 0.015 mg/l
00.20.40.62026-01-20: below 0.03 mg/l2026-10-05: below 0.03 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2026: avg 44 · min 20 % saturation
2550751001252026-01-20: 19.9 % saturation2026-10-05: 68.8 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

12.6–13.5 °C

Warm water holds less oxygen. There is no river standard for temperature here.

051015202026-01-20: 12.6 °C2026-10-05: 13.5 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: Alkalinity to pH 4.5 as CaCO3 (MILLIGRAM PER LITRE)

EA sampling point SW-73010031 · 430 readings of 117 tests since 2022.

DateResultUnitSample
2026-10-05 11:51220MILLIGRAM PER LITREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-01-20 12:53210MILLIGRAM PER LITREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-10-28 10:44230MILLIGRAM PER LITREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-01-13 12:10350MILLIGRAM PER LITREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-10-25 14:17220MILLIGRAM PER LITREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-01-11 12:33220MILLIGRAM PER LITREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-10-24 12:02230MILLIGRAM PER LITREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-02-27 09:34240MILLIGRAM PER LITREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2022-11-16 10:49240MILLIGRAM PER LITREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)

Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the River Taw.