← Tockington Mill Lodge
Spill evidence · River Hub
Tockington Mill Lodge
Combined sewer overflow · WXW00738 · feeds TOCKINGTON STW CATCHMENT
Wet weather
The discharge
- Spill day
- Thursday, 5 February 2026
- Started
- 5 Feb 2026, 20:28
- Ended
- 12 Feb 2026, 02:28
- Duration
- 6 days 6 hours
- Receiving water
- Chestle Pill
- Parish
- Olveston
Rainfall evidence
Daily rainfall at the matched gauge (Frampton Cotterell Mill) for the spill day and the days before. A spill is dry when every day in the window is ≤ 0.25 mm.
1-day window: Wet weather3-day window: Wet weather4-day window: Wet weather
| Date | Rainfall | |
|---|---|---|
| 05/02/2026 (spill day) | 5.6 mm | rain |
| 04/02/2026 | 0.6 mm | rain |
| 03/02/2026 | 3.8 mm | rain |
| 02/02/2026 | 0.4 mm | rain |
| 01/02/2026 | 9 mm | rain |
River flow that day: 40.511 m³/s. Verify at the EA rainfall station.
Gauge proximity
Outlet (red) vs matched rain gauge (blue), 7.3 km apart. Closer means the rainfall reading is more representative of the overflow.
Loading map…
Severity & context
- Bathing water
- Not Applicable
- Shellfish water
- Not Applicable
- Ahead of the works
- Yes — the treatment works' own overflow stayed shut that day, so capacity was available. Avoidable.
Method & provenance. Dry/wet classification is decided by rainfall at the nearest EA gauge — ≤ 0.25 mm on the spill day and each preceding day of the window (how we classify). Spill data: Environment Agency EDM (outlet WXW00738). Rainfall: EA Hydrology gauge aaf8fe03-f3db-43f4-8ce6-701ebfac9ca7_5302070SC. A dry spill is precautionary evidence of a likely fault, not proof of an offence — we test the rainfall, not the works' flow. Generated by Lower Severn Vale Data.