EA sampling point
River Hayle at Relubbus
Sampled by the Environment Agency on 5 visits from 2020 to 2022.
Ammonia
2020–2022: avg 0.015 · max 0.015 mg/lHigh ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1
Dissolved oxygen
2020–2022: avg 100 · min 97 % saturationHigh ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50
Water temperature
12.4–15.4 °CWarm water holds less oxygen. There is no river standard for temperature here.
Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.
Every reading: Cadmium (MICROGRAM PER LITRE)
EA sampling point SW-82221844 · Hayle · 124 readings of 48 tests since 2022.
| Date | Result | Unit | Sample |
|---|---|---|---|
| 2022-07-21 12:10 | 1.3 | MICROGRAM PER LITRE | RIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY) |
| 2022-06-24 11:12 | 1.3 | MICROGRAM PER LITRE | RIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY) |
| 2022-06-23 12:04 | 1.3 | MICROGRAM PER LITRE | RIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY) |
| 2022-04-13 11:24 | 1.2 | MICROGRAM PER LITRE | RIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY) |
| 2022-04-12 15:30 | 1.2 | MICROGRAM PER LITRE | RIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY) |
Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the Hayle & Red River.