EA sampling point
River Seaton downstream of Railway Culvert
Sampled by the Environment Agency on 5 visits from 2023 to 2025.
Dissolved oxygen
2023–2025: avg 100 · min 98 % saturationHigh ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50
Water temperature
9.1–14.4 °CWarm water holds less oxygen. There is no river standard for temperature here.
Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.
Every reading: Barium, Dissolved (MICROGRAM PER LITRE)
EA sampling point SW-81310293 · Seaton · 296 readings of 53 tests since 2022.
| Date | Result | Unit | Sample |
|---|---|---|---|
| 2025-01-29 11:30 | < 10 | MICROGRAM PER LITRE | RIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (LOCAL MONITORING) |
| 2024-09-30 11:10 | < 10 | MICROGRAM PER LITRE | ANY WATER · PLANNED INVESTIGATION (LOCAL MONITORING) |
| 2024-08-14 11:25 | < 10 | MICROGRAM PER LITRE | RIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (LOCAL MONITORING) |
| 2024-05-24 11:10 | < 10 | MICROGRAM PER LITRE | RIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (LOCAL MONITORING) |
| 2024-04-24 11:32 | < 10 | MICROGRAM PER LITRE | RIVER / RUNNING SURFACE WATER · PLANNED INVESTIGATION (LOCAL MONITORING) |
| 2022-03-24 13:25 | < 10 | MICROGRAM PER LITRE | RIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS) |
| 2022-03-24 13:05 | < 10 | MICROGRAM PER LITRE | RIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS) |
| 2022-03-24 12:45 | < 10 | MICROGRAM PER LITRE | RIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS) |
Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the River Fowey.