Why it keeps happening
Three things we can measure in the data. None of them proves a cause on its own, but each points at a different kind of infrastructure problem.
A discharge in dry weather is not an exceptional circumstance, so it is not permitted on any reading of regulation 4.
See the 3 →A strong signal, not a finding. We cannot see whether flow is transferred to another works for treatment, and the permitted figure is not always published.
See the 0 →Rainfall across the catchment does not explain a discharge that an overflow's own treatment works did not share.
See the 10 →Where the indicators concentrate
| Overflow | Hours | Dry | What it points to | Verdict |
|---|---|---|---|---|
| Alfriston Ceo - 108359 | 26 | 16 | Dry spilling | No action |
| Hellingly, - 108247CSO | 376 | 10 | Spills before its works | No action |
| Upper Dicker Ceo - 108776 | 360 | 2 | Spills before its works | No action |
| Huggetts Farm Horam Ceo - 108258 | 157 | 0 | Spills before its works | No action |
| Littlebrook Waldron Ceo - 108274 | 151 | 0 | Spills before its works | No action |
| Punnetts Town Ceo - 108320 | 35 | 0 | Spills before its works | No action |
| Upper Horsebridge Ceo - 111334 | 6 | 0 | Spills before its works | No action |
| Horebeech Lane Horam Ceo - 108254 | 1 | 2 | Spills before its works | No action |
| Bramble Drive Hailsham, - 108379CSO | 25 | 0 | Spills before its works | No action |
| Three Cups Corner Ceo - 108362 | 2 | 0 | Spills before its works | No action |
Hours are the last full year; dry spills are since 2020. Verdict is whether a measure is linked to the overflow — see the gaps.
What this analysis cannot see
These indicators are measured from spill timing and rainfall alone. They cannot see misconnections, the quality of effluent from a works that is running normally, flow transferred between works for treatment, a company's maintenance history, or the periods when a monitor was offline. Because a quiet monitor records nothing, every count here is a floor, not a total.