EA sampling point

Yeading Brook at Headstone Manor

Sampled by the Environment Agency on 11 visits from 2020 to 2022. Phosphate averages poor, below the good standard. Dissolved oxygen averages moderate, below the good standard. Ammonia is good or better. Averages are over 2020–2022.

Phosphate

2020–2022: avg 0.304 · max 0.560 mg/l

Band, 2020–2022 average: 0.304 · Poor

00.250.50.751202120222022-01-27: 0.22 mg/l2022-02-11: 0.25 mg/l2022-03-15: 0.24 mg/l2022-04-01: 0.34 mg/l2022-05-27: 0.46 mg/l2022-06-29: 0.56 mg/l2022-07-21: 0.37 mg/l2022-08-26: 0.22 mg/l2022-09-07: 0.18 mg/l2022-10-28: 0.26 mg/l2022-11-14: 0.24 mg/l
High ≤ 0.036Good ≤ 0.069Moderate ≤ 0.173Poor ≤ 1.003Bad > 1.003

Ammonia

2020–2022: avg 0.236 · max 0.710 mg/l

Band, 2020–2022 average: 0.236 · Good

00.250.50.751202120222022-01-27: 0.19 mg/l2022-02-11: 0.71 mg/l2022-03-15: 0.12 mg/l2022-04-01: 0.2 mg/l2022-05-27: 0.14 mg/l2022-06-29: 0.65 mg/l2022-07-21: 0.26 mg/l2022-08-26: 0.1 mg/l2022-09-07: 0.077 mg/l2022-10-28: 0.083 mg/l2022-11-14: 0.07 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2020–2022: avg 65 · min 35 % saturation

Band, 2020–2022 average: 65 · Moderate

406080100120202120222022-01-27: 80.6 % saturation2022-02-11: 75.1 % saturation2022-03-15: 82.1 % saturation2022-04-01: 79.7 % saturation2022-05-27: 87.1 % saturation2022-06-29: 49.3 % saturation2022-07-21: 34.6 % saturation2022-08-26: 54.7 % saturation2022-09-07: 56.3 % saturation2022-10-28: 64.9 % saturation2022-11-14: 54.1 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

7.2–18.8 °C

Warm water holds less oxygen. There is no river standard for temperature here.

0102030202120222022-01-27: 7.7 °C2022-02-11: 7.2 °C2022-03-15: 10.2 °C2022-04-01: 7.7 °C2022-05-27: 15.1 °C2022-06-29: 15.8 °C2022-07-21: 18.8 °C2022-08-26: 17.7 °C2022-09-07: 18.3 °C2022-10-28: 15 °C2022-11-14: 12.5 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: 2-Phenoxypropionic acid :- {PPA} (MICROGRAM PER LITRE)

EA sampling point TH-RSN0706 · Yeading Brook · 1,293 readings of 119 tests since 2022.

DateResultUnitSample
2022-11-14 12:510.0066MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-10-28 11:020.015MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-09-07 14:320.011MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-08-26 12:120.0068MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-07-21 13:000.017MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-06-29 12:160.011MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-05-27 15:58< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-04-01 14:01< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-03-15 12:07< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-02-11 14:17< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-01-27 12:58< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)

Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the River Crane.