EA sampling point

Sunbury, Chertsey Road, Well3, 2m :Tq07/

Sampled by the Environment Agency on 3 visits in 2026.

Phosphate

2026: avg 0.220 · max 0.230 mg/l
00.10.20.32026-01-14: 0.21 mg/l2026-05-18: 0.22 mg/l2026-07-31: 0.23 mg/l
High ≤ 0.036Good ≤ 0.069Moderate ≤ 0.173Poor ≤ 1.003Bad > 1.003

Ammonia

2026: avg 0.015 · max 0.015 mg/l
00.20.40.62026-01-14: below 0.03 mg/l2026-05-18: below 0.03 mg/l2026-07-31: below 0.03 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2026: avg 73 · min 70 % saturation
60801001202026-01-14: 73.1 % saturation2026-05-18: 69.6 % saturation2026-07-31: 75.4 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

12.5–16.2 °C

Warm water holds less oxygen. There is no river standard for temperature here.

051015202026-01-14: 12.5 °C2026-05-18: 13.7 °C2026-07-31: 16.2 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: Conductivity at 25 C (MICROSIEMENS PER CENTIMETRE)

EA sampling point TH-PGWU1554 · Portlane Brook · 1,343 readings of 327 tests since 2022.

DateResultUnitSample
2026-07-31 09:51725MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-05-18 11:39740MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-01-14 10:36783MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-10-27 09:40838MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-05-22 13:20804MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-01-28 10:53785MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-10-23 12:15801MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-07-03 10:37804MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-01-17 13:33776MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-10-04 11:10787MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-07-03 11:58759MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-06-15 10:57712MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-01-26 10:05712MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2022-10-19 09:48713MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2022-08-22 11:02720MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2022-06-30 15:11732MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)

Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the River Crane.