Why it keeps happening
Three things we can measure in the data. None of them proves a cause on its own, but each points at a different kind of infrastructure problem.
A discharge in dry weather is not an exceptional circumstance, so it is not permitted on any reading of regulation 4.
See the 19 →A strong signal, not a finding. We cannot see whether flow is transferred to another works for treatment, and the permitted figure is not always published.
See the 0 →Rainfall across the catchment does not explain a discharge that an overflow's own treatment works did not share.
See the 7 →Where the indicators concentrate
| Overflow | Hours | Dry | What it points to | Verdict |
|---|---|---|---|---|
| Wardington pumping station | 358 | 109 | Dry spilling | No action |
| Boddington STW | 1,080 | 81 | Very long spills | On record |
| Farnborough STW | 434 | 90 | High spill frequency | On record |
| Eydon STW | 872 | 49 | Dry spilling | On record |
| Shutford STW | 255 | 137 | Dry spilling | On record |
| Marston St Lawrence pumping station | 150 | 6 | Spills before its works | No action |
| Banbury Road (kings Sutton) pumping station | 144 | 13 | Spills before its works | No action |
| Tackley pumping station & Storm pumping station | 47 | 13 | Spills before its works | No action |
| Hanwell STW | 471 | 28 | Dry spilling | On record |
| Cropredy STW | 453 | 68 | Dry spilling | On record |
Hours are the last full year; dry spills are since 2020. Verdict is whether a measure is linked to the overflow — see the gaps.
What this analysis cannot see
These indicators are measured from spill timing and rainfall alone. They cannot see misconnections, the quality of effluent from a works that is running normally, flow transferred between works for treatment, a company's maintenance history, or the periods when a monitor was offline. Because a quiet monitor records nothing, every count here is a floor, not a total.