What the regulator requires
A measure is a specific action the regulator requires the water company to take at a named site — to investigate a problem, keep monitoring it, or physically fix it — each with a completion date. These are the legally binding measures on record for this catchment: what each requires, and what to watch.
These measures are legally binding. Each one is a dated, site-specific requirement the company must deliver.
The Water Industry National Environment Programme is how the Environment Agency turns statutory duties into named obligations at named sites, with a completion date attached. Where a measure requires a physical upgrade, the Agency writes the result into the site's environmental permit — and from that point the requirement is criminally enforceable.
The measure itself is public. What is not published is the water company's action to comply with it — its delivery is reported to the regulator and scored, but the underlying work, and whether a measure has actually resolved the problem on the ground, is not on the public record. What to watch is slippage: a measure can be re-dated or re-scoped, and until the permit is varied the obligation has not changed.
What the types mean
A physical upgrade — bigger storage, better treatment, more capacity. This is the only type that actually fixes the problem on the ground.
A study of the cause. It produces a report, not a repair — an investigation must lead to an improvement before anything changes.
Installing or running instruments to measure the problem. Necessary evidence, but on its own it fixes nothing — it too has to be followed by an improvement.
So an overflow whose only measures are investigations or monitoring is being looked at, not yet fixed. On the gaps page, only a measure that is still active counts as action — a measure completed while the overflow is still failing does not.
| Reference | Driver | Type | What it requires | Status | Attached to |
|---|---|---|---|---|---|
| 08TW101108 · ui | EnvAct_INV4 | Investigation | Storm Overflows investigation Abbeydale Road- Storm Overflows investigation | Due 2027-28 | Lower Brent |
| 08TW101108 · uk | EnvAct_INV4 | Investigation | Storm Overflows investigation Cricklewood Broadway- Storm Overflows investigation | Due 2027-28 | Lower Brent |
| 08TW101108 · ud | EnvAct_INV4 | Investigation | Storm Overflows investigation Cricklewood Lane, Cricklewood- Storm Overflows investigation | Due 2027-28 | Dollis Brook and Upper Brent |
| 08TW101108 · ul | EnvAct_INV4 | Investigation | Storm Overflows investigation Edgware Road- Storm Overflows investigation | Due 2027-28 | Silk Stream and Edgware Brook |
| 08TW101108 · uh | EnvAct_INV4 | Investigation | Storm Overflows investigation Fairfield Avenue 1- Storm Overflows investigation | Due 2027-28 | Dollis Brook and Upper Brent |
| 08TW101108 · ue | EnvAct_INV4 | Investigation | Storm Overflows investigation Gordon Road- Storm Overflows investigation | Due 2027-28 | Dollis Brook and Upper Brent |
| 08TW101108 · ty | EnvAct_INV4 | Investigation | Storm Overflows investigation South Ealing Road, W5- Storm Overflows investigation | Due 2027-28 | Lower Brent |
| 08TW101108 · it | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at ALICIA AVENUE CSO UNPERMITTED CSO | Due 2027-28 | Wealdstone Brook |
| 08TW101108 · es | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at ALLENDALE ROAD CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · iv | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at BOYNE AVENUE, HENDON UNPERMITTED CSO | Due 2027-28 | Dollis Brook and Upper Brent |
| 08TW101108 · ix | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at BRENT CROSS FLYOVER UNPERMITTED CSO | Due 2027-28 | Dollis Brook and Upper Brent |
| 08TW101108 · iz | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at BRENT VALLEY GOLF COURSE , LB EALING UNPERMITTED CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · ep | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at BRENTFIELD GARDENS CSO | Due 2027-28 | Dollis Brook and Upper Brent |
| 08TW101108 · jo | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at CHURCH ROAD BRENT LODGE PARK (BUNNY PARK) UNPERMITTED CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · jq | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at COLIN CRESCENT, COLINDALE UNPERMITTED CSO | Due 2027-28 | Silk Stream and Edgware Brook |
| 08TW101108 · jr | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at CONOLLY ROAD HANWELL UNPERMITTED CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · fh | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at DAINTRY CLOSE CSO | Due 2027-28 | Wealdstone Brook |
| 08TW101108 · ez | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at DISTRICT ROAD CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · kb | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at EAST LANE CSO 1 UNPERMITTED CSO | Due 2027-28 | Wealdstone Brook |
| 08TW101108 · ew | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at EASTCOTE AVENUE CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · ke | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at ELMS ROAD CSO UNPERMITTED CSO | Due 2027-28 | Wealdstone Brook |
| 08TW101108 · kf | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at FALLODEN COURT & BROOKLAND RISE UNPERMITTED CSO | Due 2027-28 | Dollis Brook and Upper Brent |
| 08TW101108 · kk | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at FRANCIS ROAD SPILL UNPERMITTED CSO | Due 2027-28 | Wealdstone Brook |
| 08TW101108 · ey | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at GARDEN WAY CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · ko | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at GRANVILLE ROAD UNPERMITTED CSO | Due 2027-28 | Dollis Brook and Upper Brent |
| 08TW101108 · ev | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at HANGER LANE CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · fc | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at HIGHFIELD ROAD JCT WITH BROOKSIDE ROAD CSO | Due 2027-28 | Dollis Brook and Upper Brent |
| 08TW101108 · ku | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at HURSTWOOD ROAD WEST UNPERMITTED CSO | Due 2027-28 | Dollis Brook and Upper Brent |
| 08TW101108 · dk | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at KENDAL ROAD (1), CULLINGWORTH ROAD CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · ky | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at KINGTHORPE TERRACE UNPERMITTED CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · di | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at LEOPOLD ROAD, CHURCH PATH CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · ff | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at LINDSAY DRIVE, FALCON WAY CSO | Due 2027-28 | Wealdstone Brook |
| 08TW101108 · dg | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at LONGSTONE AVE, DRAYTON ROAD CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · fg | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at LYON PARK AVENUE CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · lf | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at MAYS LANE OVERFLOW UNPERMITTED CSO | Due 2027-28 | Dollis Brook and Upper Brent |
| 08TW101108 · lj | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at NEASDEN STATION UNPERMITTED CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · ln | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at NORTH END ROAD CSO UNPERMITTED CSO | Due 2027-28 | Wealdstone Brook |
| 08TW101108 · mb | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at RUISLIP ROAD EAST UNPERMITTED CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · mi | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at ST PAULS AVENUE CSO UNPERMITTED CSO | Due 2027-28 | Wealdstone Brook |
| 08TW101108 · mj | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at STAG LANE CSO UNPERMITTED CSO | Due 2027-28 | Silk Stream and Edgware Brook |
| 08TW101108 · fb | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at SUDBURY HEIGHTS AVE, ALLENDALE ROAD CSO | Due 2027-28 | Lower Brent |
| 08TW101108 · fa | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at TRUMPERS WAY, W7 SPS | Due 2027-28 | Lower Brent |
| 08TW101108 · fi | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at WENTWORTH ROAD CSO | Due 2027-28 | Dollis Brook and Upper Brent |
| 08TW101108 · fn | EnvAct_INV4 | Investigation | Investigate the cause of the spills Storm Overflows investigation at WESTERN WAY CSO | Due 2027-28 | Dollis Brook and Upper Brent |
| 08TW101099 · a | ENVAct_IMP2 | Improvement | Default scheme: Investigation and Solution in AMP 8: 1,285m3 storage, 20m3 screen Storm Overflows action at ALICIA AVENUE CSO UNPERMITTED CSO | Due 2029-30 | Wealdstone Brook |
| 08TW101071 · a | ENVAct_IMP2 | Improvement | Default scheme: Investigation and Solution in AMP 8: 1,285m3 storage, 20m3 screen Storm Overflows action at DAINTRY CLOSE CSO | Due 2029-30 | Wealdstone Brook |
| 08TW101069 · a | ENVAct_IMP2 | Improvement | Default scheme: Investigation and Solution in AMP 8: 1,285m3 storage, 20m3 screen Storm Overflows action at HONEYPOT LANE (Winchester Avenue) CSO CSO | Due 2029-30 | Wealdstone Brook |
| 08TW101068 · a | ENVAct_IMP2 | Improvement | Investigation and Solution in AMP 8: UPM - New sewers and 10m diameter, 3m height storage tank. Bricking up of CSO link pipe. Storm Overflows action at LEESIDE CRESCENT (FORMERLY BROOKSIDE ROAD, GOLDERS GREEN) | Due 2029-30 | Dollis Brook and Upper Brent |
48 of 48 measures shown. A measure whose completion date has passed is shown as Complete; the water company's actual delivery against it is reported to the regulator but not published here.
There is no public change log
The live WINEP spreadsheet is internal, and there is no versioned public comparison or published reasons when a measure is re-dated or dropped. The only way to hold slippage to account is to archive every annual release and diff it yourself.
The 2027 pressure point
Most investigations must complete by 30 April 2027 to feed the 2030–35 programme. That date — not 2030 — is the one to hold: an investigation that slips past it cannot shape the next round of funded schemes.