Who is fixing it

What the regulator requires

A measure is a specific action the regulator requires the water company to take at a named site — to investigate a problem, keep monitoring it, or physically fix it — each with a completion date. These are the legally binding measures on record for this catchment: what each requires, and what to watch.

These measures are legally binding. Each one is a dated, site-specific requirement the company must deliver.

The Water Industry National Environment Programme is how the Environment Agency turns statutory duties into named obligations at named sites, with a completion date attached. Where a measure requires a physical upgrade, the Agency writes the result into the site's environmental permit — and from that point the requirement is criminally enforceable.

The measure itself is public. What is not published is the water company's action to comply with it — its delivery is reported to the regulator and scored, but the underlying work, and whether a measure has actually resolved the problem on the ground, is not on the public record. What to watch is slippage: a measure can be re-dated or re-scoped, and until the permit is varied the obligation has not changed.

What the types mean

Improvement

A physical upgrade — bigger storage, better treatment, more capacity. This is the only type that actually fixes the problem on the ground.

Investigation

A study of the cause. It produces a report, not a repair — an investigation must lead to an improvement before anything changes.

Monitoring

Installing or running instruments to measure the problem. Necessary evidence, but on its own it fixes nothing — it too has to be followed by an improvement.

So an overflow whose only measures are investigations or monitoring is being looked at, not yet fixed. On the gaps page, only a measure that is still active counts as action — a measure completed while the overflow is still failing does not.

38
Measures in this catchment
WINEP, current record
38
Still active
not yet past their date
0
Assumed complete
completion date has passed
10
Are physical improvements
the rest investigate or monitor
ReferenceDriverTypeWhat it requiresStatusAttached to
08SO102509 · aU_MON4Monitoring
U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring
Battle WTW
Due 2026-27Brede
08SO102682 · aU_MON3Monitoring
U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor
BATTLE WWTW
Due 2026-27Brede
08SO102532 · aU_MON4Monitoring
U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring
Fairlight WTW
Due 2026-27FAIRLIGHT
08SO102742 · aU_MON3Monitoring
U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor
FAIRLIGHT WWTW
Due 2026-27Marsham and Pannel Sewers
08SO102746 · aU_MON3Monitoring
U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor
FERRY HILL WINCHELSEA WWTW
Due 2026-27Brede
08SO102449 · aU_MON4Monitoring
U_MON4c - PR24 U_MON4 from U_INV2 investigation including civils
Ferry Hill WTW
Due 2026-27Brede
08SO102490 · aU_MON4Monitoring
U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring
Guestling Green WTW
Due 2026-27GUESTLING GREEN
08SO102765 · aU_MON3Monitoring
U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor
GUESTLING GREEN WWTW
Due 2026-27Marsham and Pannel Sewers
08SO102568 · aU_MON4Monitoring
U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring
ICKLESHAM WTW
Due 2026-27ICKLESHAM
08SO102785 · aU_MON3Monitoring
U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor
ICKLESHAM WWTW
Due 2026-27Brede
08SO102569 · aU_MON4Monitoring
U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring
IDEN WTW
Due 2026-27IDEN
08SO102525 · aU_MON4Monitoring
U_MON4c - PR24 U_MON4 from U_INV2 investigation including civils
Staplecross WTW
Due 2026-27STAPLECROSS
08SO102887 · aU_MON3Monitoring
U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor
STAPLECROSS WWTW
Due 2026-27Tillingham
08SO102543 · aU_MON4Monitoring
U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring
Stubbs Lane Brede WTW
Due 2026-27STUBBS LANE BREDE
08SO102896 · aU_MON3Monitoring
U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor
STUBBS LANE BREDE WWTW
Due 2026-27Brede
08SO102592 · aU_MON4Monitoring
U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring
WESTFIELD WTW
Due 2026-27Doleham Ditch
08SO102924 · aU_MON3Monitoring
U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor
WESTFIELD WWTW
Due 2026-27Doleham Ditch
08SO101079 · aWFD_NDLS_Chem2No deterioration
Prevent any deterioration
Battle WTW
Due 2026-27Brede
08SO104950 · qiEnvAct_INV4Investigation
Investigation to determine the target number of spills from the storm overflow to protect the environment and demonstrate no local adverse ecological impact
FAIRLIGHT SSO
Due 2027-28Marsham and Pannel Sewers
08SO104950 · qyEnvAct_INV4Investigation
Investigation to determine the target number of spills from the storm overflow to protect the environment and demonstrate no local adverse ecological impact
GUESTLING GREEN SSO
Due 2027-28Marsham and Pannel Sewers
08SO104950 · psEnvAct_INV4Investigation
Investigation to determine the target number of spills from the storm overflow to protect the environment and demonstrate no local adverse ecological impact
STUBBS LANE BREDE SSO
Due 2027-28Brede
08SO103819 · aWFD_INVInvestigation
Investigations for actions to improve water quality in terms of relevant WFD status objectives.
UDIMORE WTW
Due 2027-28Brede
08SO104950 · qhEnvAct_INV4Investigation
Investigation to determine the target number of spills from the storm overflow to protect the environment and demonstrate no local adverse ecological impact
WESTFIELD SSO
Due 2027-28Doleham Ditch
08SO104037 · aWFD_NDNo deterioration
Amend WFD ND BOD permit
BATTLE
Due 2029-30Brede
08SO104037 · bWFD_NDNo deterioration
Amend WFD ND Total P permit
BATTLE
Due 2029-30Brede
08SO101079 · bWFD_ND_CHEM3No deterioration
Prevent any deterioration
Battle WTW
Due 2029-30Brede
08SO104120 · aWFD_NDNo deterioration
Amend Ammonia permit
FAIRLIGHT
Due 2029-30FAIRLIGHT
08SO103921 · aEnvAct_IMP2Improvement
SuDS + Storage
FAIRLIGHT SSO
Due 2029-30Marsham and Pannel Sewers
08SO104709 · aWFD_IMPgImprovement
Amend total P permit
Ferry Hill Winchelsea
Due 2029-30FERRY HILL WINCHELSEA
08SO103724 · aWFD_IMPmImprovement
Amend Total P permit
GUESTLING GREEN
Due 2029-30GUESTLING GREEN
08SO103925 · aEnvAct_IMP2Improvement
SuDS + Storage
GUESTLING GREEN SSO
Due 2029-30Marsham and Pannel Sewers
08SO104050 · aWFD_IMPmImprovement
Amend Total P permit
ICKLESHAM
Due 2029-30ICKLESHAM
08SO104100 · aWFD_IMPmImprovement
Amend Total P permit
STAPLECROSS
Due 2029-30STAPLECROSS
08SO104052 · aWFD_NDNo deterioration
Amend WFD ND Total P permit
STUBBS LANE BREDE
Due 2029-30STUBBS LANE BREDE
08SO104053 · aWFD_IMPmImprovement
Amend Total P permit
WESTFIELD
Due 2029-30Doleham Ditch
08SO104069 · aWFD_IMPgImprovement
Amend Total P permit
WINCHELSEA BEACH
Due 2029-30Brede
08SO103915 · aEnvAct_IMP2Improvement
Wetland + Lining
STUBBS LANE BREDE SSO
Due 2034-35Brede
08SO103920 · aEnvAct_IMP2Improvement
SuDS + Storage
WESTFIELD SSO
Due 2034-35Doleham Ditch

38 of 38 measures shown. A measure whose completion date has passed is shown as Complete; the water company's actual delivery against it is reported to the regulator but not published here.

There is no public change log

The live WINEP spreadsheet is internal, and there is no versioned public comparison or published reasons when a measure is re-dated or dropped. The only way to hold slippage to account is to archive every annual release and diff it yourself.

The 2027 pressure point

Most investigations must complete by 30 April 2027 to feed the 2030–35 programme. That date — not 2030 — is the one to hold: an investigation that slips past it cannot shape the next round of funded schemes.