← Town Quay pumping station, Fowey

Spill evidence · River Hub

Town Quay pumping station, Fowey

Pumping station overflow · SBB01268 · feeds FOWEY STW
Wet weather

The discharge

Spill day
Wednesday, 3 December 2025
Started
3 Dec 2025, 04:03
Ended
3 Dec 2025, 05:28
Duration
1 hour 24 minutes
Receiving water
Pont Pill
Parish
Fowey

Rainfall evidence

Daily rainfall at the matched gauge (St Blazey) for the spill day and the days before. A spill is dry when every day in the window is ≤ 0.25 mm.

1-day window: Wet weather3-day window: Wet weather4-day window: Wet weather
DateRainfall
03/12/2025 (spill day)7.7 mmrain
02/12/20250.4 mmrain
01/12/202513.5 mmrain
30/11/202512.6 mmrain
29/11/20252.1 mmrain

River flow that day: 12.8 m³/s. Verify at the EA rainfall station.

Gauge proximity

Outlet (red) vs matched rain gauge (blue), 7.3 km apart. Closer means the rainfall reading is more representative of the overflow.

Loading map…

Severity & context

Bathing water
Readymoney Cove
Shellfish water
Fowey
Ahead of the works
No — the works was also overflowing that day.
EA annual return (2025)
198 counted spills · 635 h total
Monitor uptime (2025)
100% operational
Method & provenance. Dry/wet classification is decided by rainfall at the nearest EA gauge — ≤ 0.25 mm on the spill day and each preceding day of the window (how we classify). Spill data: Environment Agency EDM (outlet SBB01268). Rainfall: EA Hydrology gauge 21a6664c-9625-46be-bc33-176bb5419e64. A dry spill is precautionary evidence of a likely fault, not proof of an offence — we test the rainfall, not the works' flow. Generated by River Fowey Data.