← Rear Imperial Hotel, Exeter

Spill evidence · River Hub

Rear Imperial Hotel, Exeter

Combined sewer overflow · SBB01009 · feeds EXETER STW
Wet weather

The discharge

Spill day
Tuesday, 9 September 2025
Started
9 Sept 2025, 17:06
Ended
9 Sept 2025, 17:22
Duration
16 minutes
Receiving water
Exe (Creedy to Estuary)
Parish
Upton Pyne

Rainfall evidence

Daily rainfall at the matched gauge (Exeter Met Office) for the spill day and the days before. A spill is dry when every day in the window is ≤ 0.25 mm.

1-day window: Wet weather3-day window: Wet weather4-day window: Wet weather
DateRainfall
09/09/2025 (spill day)23.9 mmrain
08/09/20250 mmdry
07/09/20252.7 mmrain
06/09/20253.3 mmrain
05/09/20250.1 mmdry

River flow that day: 1.62 m³/s. Verify at the EA rainfall station.

Gauge proximity

Outlet (red) vs matched rain gauge (blue), 4.6 km apart. Closer means the rainfall reading is more representative of the overflow.

Loading map…

Severity & context

Bathing water
Not Applicable
Shellfish water
Exe Estuary
Ahead of the works
No — the works was also overflowing that day.
EA annual return (2025)
9 counted spills · 4 h total
Monitor uptime (2025)
99% operational

⚠ Coastal / tidal location — very short discharges around high tide can be monitor artefacts; corroborate with tide times before relying on short events here.

Method & provenance. Dry/wet classification is decided by rainfall at the nearest EA gauge — ≤ 0.25 mm on the spill day and each preceding day of the window (how we classify). Spill data: Environment Agency EDM (outlet SBB01009). Rainfall: EA Hydrology gauge ffba0119-08bc-4cbb-beab-d3c3ae6bfb32. A dry spill is precautionary evidence of a likely fault, not proof of an offence — we test the rainfall, not the works' flow. Generated by River Exe Data.